Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20230519-005 TPO 60 mil Technicial Data Sheet
•Excellent fire resistant assemblies •Environmentally friendly and stable formulation •Excellent resistance to impact and low temperatures •Excellent chemical resistance to acids, bases and restaurant exhaust emissions •UL 2218 Class 4 hail rating •Exceptional resistance to heat, solar UV, ozone and oxidation •Manufactured using a hot-melt extrusion process for complete scrim encapsulation •Enhanced with the OctaGuard XT weathering package •Standard Colors: •Special Colors: * VersiWeld HS Special Color TPO membranes are available in limited sizes. Refer to Versico’s VersiWeld HS TPO Special Color Program Sell Sheet for details. Sustainable Attributes Versico Roofing Systems’ focus has always been innovation – Innovation to solve problems, improve performance, reduce labor, and above all, improve sustainability. Versico is committed to driving sustainable and efficient processes in the design and manufacturing of our products. •Up to 10% pre-consumer recycled content •Fully recyclable when used in mechanically attached systems •3rd-party verified Environmental Product Declaration available •NSF P151 certification for rainwater catchment* •California Title 24 compliant** •Free of Living Building Challenge red list chemicals * White only, produced in Tooele, UT ** White and Tan only VersiWeld® TPO Reinforced Membrane Overview Versico’s VersiWeld TPO reinforced membrane is a premium, heat- weldable, single-ply thermoplastic polyolefin (TPO) sheet designed for new roof construction and re-roofing applications. VersiWeld High Slope (HS) membrane is formulated with additional flame retardant for higher- slope fire code approvals. VersiWeld Plus is 80 mils (2.03 mm) thick for significantly higher strength and weatherability. VersiWeld TPO membranes use advanced polymerization technology that combines the flexibility of ethylene-propylene (EP) rubber with the heat weldability of polypropylene. All VersiWeld TPO membranes include OctaGuard XT™, an industry-leading, state-of-the-art weathering package. OctaGuard XT technology enables VersiWeld TPO to withstand the extreme weatherability testing that is intended to simulate exposure to severe climates. Physical properties of the membrane are enhanced by a strong polyester fabric that is encapsulated between the TPO-based top and bottom plies. The combination of the fabric and TPO plies provides high breaking and tearing strength, as well as excellent puncture resistance. The relatively smooth surface of the membrane produces a total surface fusion weld that results in a consistent, watertight, monolithic roof assembly. The membrane is environmentally friendly and safe to install. Features and Benefits •VersiWeld TPO available in 4-, and 6-ft (121.92 cm and 182.88 cm) perimeter sheets and 8-, 10-, and 12-ft (243.84 cm, 304.80 cm, and 365.76 cm) VersiWeld field sheets* •Outstanding puncture resistance BUILDING VALUE TECHNICAL DATA BULLETIN White Slate Gray Gray Med Bronze Tan Terra Cotta Patina Green Rock Brown ALL WORK SUBJECT TO FIELD INSPECTION Installation VersiWeld TPO roofing systems are quick to install, as minimal labor and few components are required. TPO systems are installed using an Automatic Heat Welder, making sheet welding fast, clean, consistent, and easy to learn, while reducing strain on the roofing technician. Fully-Adhered – membrane is adhered to a suitable substrate utilizing an appropriate bonding adhesive Mechanically Attached – membrane is attached to the roof deck over a suitable substrate utilizing plates and fasteners which are overlapped with membrane VersiWeld TPO Reinforced Membrane TECHNICAL DATA BULLETIN Induction-Welded – membrane is attached over a suitable substrate via an induction welding tool being placed over the membrane where a fastened TPO induction welding plate is located to weld the two components together REVIEW CURRENT VERSICO SPECIFICATIONS AND DETAILS FOR SPECIFIC INSTALLATION REQUIREMENTS. Precautions •Sunglasses that filter out ultraviolet light are strongly recommended, as tan and white surfaces are highly reflective. Roofing technicians should dress appropriately and wear sunscreen. •Surfaces may become slippery due to frost and ice buildup. Exercise caution during cold conditions to prevent falls. •Care must be exercised when working close to a roof edge when the surrounding area is snow-covered, as the roof edge may not be clearly visible. •Use proper stacking procedures to ensure sufficient stability of the rolls. •Exercise caution when walking on wet membrane. Membranes may be slippery when wet. •Store membrane in the original undisturbed plastic wrap in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. Membrane that has been exposed to the weather must be prepared with Weathered Membrane Cleaner prior to hot-air welding. •Take care not to stand or place heavy objects on the edge of folded-over membrane, as this could cause a hard crease in the membrane. •Maximum sustained temperature not to exceed 160°F (71°C) for TPO membrane. •Do not use razor blades or other sharp tools to cut the APEEL Protective Film while it is still adhered to the TPO membrane as damage to the underlying membrane may occur. Pull the protective film away from the membrane prior to cutting. •Remove APEEL Protective Film by pulling towards the center of the roof. Do not remove the film by pulling towards the roof edge. •A static electric charge may develop when removing APEEL Protective Film from the surface of the membrane sheet. To avoid the possibility of ignition, lids must be closed on any flammable products and a fire extinguisher should be readily available. •Color membranes will ‘fade’ over time mainly due to the ultraviolet portion of sunlight. Since most roof surfaces are exposed to variable sunlight, some areas will be more susceptible to color changes caused by UV fading. Warranties for color membranes do not cover fading of colors. BUILDING VALUE Optional APEEL™ Protective Film: Shield Versico’s VersiWeld TPO membrane from dirt and scuffs during installation with APEEL Protective Film. Durable and easy to remove, APEEL eliminates the need for rooftop cleaning upon project completion. •Ideal for re-roofing, re-cover, and new construction projects •Simple and easy to remove •Saves time and money when compared to pressure washing •Protecting from dirt maintains maximum membrane reflectivity and long-term performance Installation Simply order membrane with APEEL, install, and remove the film to reveal a clean, new roof. •APEEL Protective Film should be removed from within areas that are to be heat-welded together. In areas that do not require heat-welding, the APEEL Protective Film can be left in place for up to 90 days without degrading due to its excellent heat- and UV-resistance . •When the installation of the entire TPO roofing system is complete, remove and discard the APEEL Protective Film. Extreme Testing for Severe Climates ASTM Standard D6878 is the material specification for Thermoplastic Polyolefin-Based Sheet Roofing. It covers material property requirements for TPO roof sheeting and includes initial and aged properties after heat and xenon-arc exposure. As stated in the scope of the standard, “the tests and property limits used to characterize the sheet are values intended to ensure minimum quality for the intended purpose.” Versico’s goal is to produce TPO that delivers maximum performance for the intended purpose of roofing membranes. Maximum performance requires the membrane to far exceed the requirements of ASTM D6878. Heat Aging accelerates the oxidation rate that roughly doubles for each 18°F (10°C) increase in roof membrane temperature. Oxidation (reaction with oxygen) is one of the primary chemical degradation mechanisms of roofing materials. Versico Testing – Heat Aging ASTM Requirement VersiWeld Requirement ASTM Test 240°F 32 weeks**>128 weeks ** Heat exposure comparable to 3,120 weeks (60 years) at 185°F for 8 hours/day. •Test specimen is a 2" by 6" (50.8 mm by 152.4 mm) piece of 45-mil (1.14 mm) membrane unbacked, placed in circulating hot-air oven. •Criterion – no visible cracks after bending aged test specimen around 3" (76.2 mm)-diameter mandrel. Q-Trac testing combines accelerated weathering with real-world conditions using an array of ten mirrors to reflect and concentrate full spectrum sunlight onto membrane test specimens. The Q-Trac device automatically tracks the sun’s path from morning to night. Also, it adjusts to compensate for seasonal changes in the sun’s altitude. Eight years in Q-Trac testing is equal to 40 years of real-world exposure. Versico requires its VersiWeld TPO membranes to pass the equivalent of 40 years of exposure in the Q-Trac. Versico Testing – Q-TRAC ASTM D6878 Requirement VersiWeld Requirements ASTM Test N/A N/A Equivalent of 40 years of exposure VersiWeld TPO Reinforced Membrane TECHNICAL DATA BULLETIN Environmental Cycling subjects the membrane to repeated cycles of heat aging, hot-water immersion, and xenon-arc exposure. •ASTM requirement – none •Versico Extreme test*: -10 days heat aging at 240°F (116°C) followed by -5 days water immersion at 158°F (70°C) followed by -5,040 kJ/m² (2000 hours at 0.70 W/m² irradiance) xenon-arc exposure * Test specimen is 2.75" (69.85 mm by 140 mm) by 5.5" piece of membrane with edges sealed. * Criterion – after 3 complete cycles, test specimens shall remain flexible and not have any cracking under 10x magnification while wrapped around a 3" (76.2 mm)-diameter mandrel. Supplemental Approvals, Statements and Characteristics: 1. VersiWeld TPO meets or exceeds the requirements of ASTM D6878 Standard Specification for Thermoplastic Polyolefin-Based Sheet Roofing. 2. VersiWeld TPO membranes conform to requirements of the US E.P.A. Toxic Leachate Test (40 CFR part 136) performed by an independent analytical laboratory. 3. VersiWeld TPO was tested for dynamic puncture resistance per ASTM D5635-04 using the most recently modified impact head. 45-mil (1.14 mm) was watertight after an impact energy of 12.5 J (9.2 ft-lbf) and 60-mil (1.52 mm) was watertight after 22.5 J (16.6 ft-lbf). 80-mil (2.03 mm) EXTRA was watertight after an impact energy of 30.0 J (22.1 ft-lbf). 4. All FM approved assemblies have been tested to pass FM 4470 for foot traffic resistance. BUILDING VALUE VersiWeld TPO Reinforced Membrane TECHNICAL DATA BULLETIN BUILDING VALUE Typical Properties and Characteristics Physical Property ASTM D6878 Requirement 45-mil (1.14 mm) 60-mil (1.52 mm) 80-mil EXTRA (2.03 mm) Tolerance on Nominal Thickness, % ASTM D751 test method +15, -10 ± 10 ± 10 ± 10 Thickness Over Scrim, in. (mm) ASTM D7635 optical method, average of 3 areas 0.015 min (0.380)0.018 typical (0.457)0.024 typical (0.610)0.034 typical (0.864) Breaking Strength, lbf (kN) ASTM D751 grab 220 (976 N) min 225 (1.0) min 320 (1.4) typical 250 (1.1) min 360 (1.6) typical 350 (1.6) min 425 (1.9) typical Elongation Break of Reinforcement, % ASTM D751 grab method 15 min 15 min 25 typical 15 min 25 typical 15 min 25 typical Tearing Strength, lbf (N) ASTM D751 proc. B 8 in. x 8 in.55 (245) min 55 (245) min 130 (578) typical 55 (245) min 130 (578) typical 55 (245) min 130 (578) typical Brittleness Point, °F (°C) ASTM D2137 -40 (-40) max -40 (-40) max -50 (-46) typical -40 (-40) max -50 (-46) typical -40 (-40) max -50 (-46) typical Linear Dimensional Change, % ASTM D1204, 6 hours at 158°F ± 1 max ± 1 max -0.2 typical ± 1 max -0.2 typical ± 1 max -0.2 typical Ozone Resistance, no cracks 7X ASTM D1149, 100 pphm, 168 hrs PASS PASS PASS PASS UV Exposure (Xenon Arc), no cracks 7X ASTM G155, min. exposure 10,080 kJ/m2 (4,000 hrs - 0.70 W/m2) PASS PASS PASS PASS Water Absorption Resistance, mass % ASTM D471 top surface only 166 hours at 158°F water ± 3.0 max ± 3.0 max 0.90 typical ± 3.0 max 0.90 typical ± 3.0 max 0.90 typical Factory Seam Strength, lbf (N) ASTM D751 grab method 66 (290) min 66 (290) min 66 (290) min 66 (290) min Field Seam Strength, lbf/in (kN/m) ASTM D1876 tested in peel No requirement 25 (4.4) min 50 (8.8) typical 25 (4.4) min 60 (10.5) typical 40 (7.0) min 70 (12.3) typical Water Vapor Permeance, Perms ASTM E96 proc. B No requirement 0.10 max 0.05 typical 0.10 max 0.05 typical 0.10 max 0.05 typical Puncture Resistance, lbf (kN) FTM 101C, method 2031 (see supplemental section)No requirement 250 (1.1) min 325 (1.4) typical 300 (1.3) min 350 (1.6) typical 400 (1.8) min 450 (2.0) typical Properties After Heat Aging ASTM D573, 32 weeks @ 240°F or 8 weeks @ 275°F No cracking when bent around 3" diameter mandrel Weight Change, % PASS No cracking ± 1.5 max PASS No cracking 1.0 max PASS No cracking 1.0 max PASS No cracking 1.0 max Typical Weights lb/ft² (kg/m²) 0.23 (1.1)0.29 (1.4)0.40 (2.0) Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED® Information Pre-consumer Recycled Content 10% Post-consumer Recycled Content 0% Manufacturing Location Senatobia, MS Tooele, UT Carlisle, PA Solar Reflective Index (SRI)99 (white) 86 (tan) 800.992.7663 • www.versico.com A SINGLE SOURCE FOR SINGLE-PLY ROOFING © 2021 Versico. Printed in U.S.A.VE-2369 - “VersiWeld Reinforced TPO Technical Data Bulletin” - 12.17.21 Versico, VersiWeld, and the Versico logo are trademarks of Versico. APEEL and OctaGuard XT are registered trademarks of Carlisle Construction Materials, LLC. LEED is a registered trademark of the U.S. Green Building Council. VersiWeld TPO Reinforced Membrane TECHNICAL DATA BULLETIN Radiative Properties for Cool Roof Rating Council (CRRC) and LEED Test Method White TPO Tan TPO Gray TPO CRRC – Initial solar reflectance ASTM C1549 0.79 0.71 0.46 CRRC – Solar reflectance after 3 years ASTM C1549 (uncleaned)0.70 0.64 0.43 CRRC – Initial thermal emittance ASTM C1371 0.90 0.86 0.89 CRRC – Thermal emittance after 3 years ASTM C1371 (uncleaned)0.86 0.87 0.88 LEED – Thermal emittance ASTM E408 0.9 0.86 0.85 SRI – Inital (Solar Reflectance Index) ASTM E1980 99 86 53 SRI – 3 year aged (Solar Reflectance Index) 85 77 48 Radiative Properties (Initial) for Special Colors Reflectance Emittance SRI Medium Bronze 0.28 0.86 29 Rock Brown 0.25 0.87 26 Slate Gray 0.38 0.87 42 Terra Cotta 0.25 0.86 25 Patina Green 0.25 0.88 25 Solar Reflectance Index (SRI) is calculated per ASTM E1980. The SRI is a measure of the roof’s ability to reject solar heat, as shown by a small temperature rise. It is defined so that a standard black (reflectance 0.05, emittance 0.90) is 0 and a standard white (reflectance 0.80, emittance 0.90) is 100. Materials with the highest SRI values are the coolest choices for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly negative values and particularly cool materials can even exceed 100.